| Safety Notes: |
- Under no circumstances should cam and groove couplings be used for compressed air or steam service!
- Pressure rating is based on the seal of the mating part.
- Pressure rating recommendations are based on the use of mating Dixon fittings at ambient temperature 70°F (21°C) with a standard seal installed. For use at elevated temperature or other unusual operating conditions, consult Dixon.
|
| How It Works: |
- To make a connection, simply slide the adapter into the coupler and with normal hand pressure, press the cam levers down.
- Uncoupling is as quick and simple as coupling. Just lift the cam arms and remove the adapter.
|
| Specifications: |
- Produced to interchange with all product produced to Commercial Item Description A-A-59326D.
|
356T6 Aluminum Part Number |
316 Stainless Steel Part Number |
Size Adapter x Male NPT |
Maximum Operating Pressure |
| 1520-F-AL |
– |
1-1/2″ x 2″ |
250 PSI |
| 2015-F-AL |
2015-F-SS |
2″ x 1-1/2″ |
250 PSI |
| 2030-F-AL |
– |
2″ x 3″ |
125 PSI |
| 3015-F-AL |
3015-F-SS* |
3″ x 1-1/2″ |
125 PSI |
| 3020-F-AL |
3020-F-SS |
3″ x 2″ |
125 PSI |
| 3040-F-AL |
– |
3″ x 4″ |
100 PSI |
| 4030-F-AL |
4030-F-SS |
4″ x 3″ |
100 PSI |
* Parts are produced as a welded fabrication.