| Compatibility & Interchange: |
|
|---|---|
| Features: |
|
| Construction: |
|
| Seal Components: |
|
| How It Works: |
|
| Additional Information: |
|
| VEP-Series | Interchange Rated Pressure Chart | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Body Size | Pressure Rating | Burst Pressure | Max. Pressure Connect3 | Max. Pressure Disconnect3 | Rated Flow ΔP=21.75 PSI | ||||
| ISO Working1 | Max. Impulse2 | Connected | Coupler | Plug | |||||
| 1/4″” | 6,000 PSI 400 Bar |
9,000 PSI 625 Bar |
24,000 PSI 1,650 Bar |
22,000 PSI 1,525 Bar |
22,000 PSI 1,525 Bar |
5,500 PSI 375 Bar |
5,500 PSI 375 Bar |
3.5 GPM | 13 L/min |
| 3/8″ | 5,500 PSI 375 Bar |
8,000 PSI 550 Bar |
22,000 PSI 1,525 Bar |
18,000 PSI 1,250 Bar |
20,000 PSI 1,375 Bar |
4,500 PSI 300 Bar |
4,500 PSI 300 Bar |
10.5 GPM | 40″ L/min |
| 1/2″ | 5,500 PSI 375 Bar |
8,000 PSI 550 Bar |
22,000 PSI 1,525 Bar |
18,000 PSI 1,250 Bar |
20,000 PSI 1,375 Bar |
4,500 PSI 300 Bar |
4,500 PSI 300 Bar |
17.5 GPM | 66 L/min |
| 3/4″ | 5,500 PSI 375 Bar |
8,000 PSI 550 Bar |
22,000 PSI 1,525 Bar |
18,000 PSI 1,250 Bar |
20,000 PSI 1,375 Bar |
4,500 PSI 300 Bar |
4,500 PSI 300 Bar |
22.7 GPM | 85 L/min |
| 1″ | 5,500 PSI 375 Bar |
7,500 PSI 525 Bar |
22,000 PSI 1,525 Bar |
14,500 PSI 1,000 Bar |
20,000 PSI 1,375 Bar |
3,625 PSI 250 Bar |
3,625 PSI 250 Bar |
32.5 GPM | 123 L/min |
| 1-1/4″ | 5,000 PSI 350 Bar |
7,000 PSI 475 Bar |
20,000 PSI 1,375 Bar |
14,500 PSI 1,000 Bar |
16,000 PSI 1,100 Bar |
3,625 PSI 250 Bar |
3,625 PSI 250 Bar |
46.4 GPM | 174 L/min |
| 1-1/2″ | 4,500 PSI 300 Bar |
5,800 PSI 400 Bar |
18,000 PSI 1,250 Bar |
12,000 PSI 8,325 Bar |
14,500 PSI 1,000 Bar |
3,000 PSI 200 Bar |
3,000 PSI 200 Bar |
95.0 GPM | 360 L/min |
| 2″ | 4,000 PSI 275 Bar |
5,000 PSI 350 Bar |
18,000 PSI 1,250 Bar |
12,000 PSI 8,325 Bar |
14,500 PSI 1,000 Bar |
3,000 PSI 200 Bar |
3,000 PSI 200 Bar |
172.5 GPM | 653 L/min |
1 Couplings impulse tested in accordance with ISO18869 for 1,000,000 cycles connected and 100,000 cycles disconnected at 133% of ISO working pressure.
2 Couplings impulse tested in accordance with ISO18869 for 100,000 cycles connected and disconnected at maximum impulse pressure listed.
3 System temperature for maximum connect/disconnect pressure must not exceed 150°F (65°C)
| VEP-Series | Code 62 Flange Pad Plug | ||||||
|---|---|---|---|---|---|---|
| Part Number |
Coupling Type |
Body Size |
Threads | Material | Length | Max. OD |
| VEP6FP6 | Plug/Male | 3/4″ | 3/4″ Code 62 Flange | Steel | 5.20″ (132.08mm) |
3.02″ (76.71mm) |
| VEP8FP8 | Plug/Male | 1″ | 1″ Code 62 Flange | Steel | 6.40″ (162.59mm) |
3.44″ (87.38mm) |
| VEP10FP10 | Plug/Male | 1-1/4″ | 1-1/4 Code 62 Flange | Steel | 6.60″ (167.64mm) |
4.03″ (102.29mm) |
| VEP12FP12 | Plug/Male | 1-1/2″ | 1-1/2 Code 62 Flange | Steel | 7.76″ (197.15mm) |
4.76″ (120.93mm) |
| VEP-Series | Code 62 Flange Pad Coupler | ||||||
|---|---|---|---|---|---|---|
| Part Number |
Coupling Type |
Body Size |
Threads | Material | Length | Max. OD |
| 6VEPFP6 | Socket/Female | 3/4″ | 3/4″ Code 62 Flange | Steel | 4.45″ (112.93mm) |
3.02″ (76.71mm) |
| 8VEPFP8 | Socket/Female | 1″ | 1″ Code 62 Flange | Steel | 5.34″ (135.64mm) |
3.44″ (87.38mm) |
| 10VEPFP10 | Socket/Female | 1-1/4″ | 1-1/4 Code 62 Flange | Steel | 5.56″ (141.10mm) |
4.03″ (102.29mm) |
| 12VEPFP12 | Socket/Female | 1-1/2″ | 1-1/2 Code 62 Flange | Steel | 6.52″ (165.71mm) |
4.76″ (120.93mm) |






Reviews